AiCARR journal
AiCARR

EDITORS IN CHIEF
Francis Allard (France)
Filippo Busato (Italy)

HONORARY EDITOR
Bjarne Olesen (Denmark)

ASSOCIATE EDITORS
Karel Kabele (Czech Republic)
Valentina Serra (Turin - Italy)

SCIENTIFIC COMMITTEE
Ciro Aprea (Italy)
William Bahnfleth (USA)
Marco Beccali (Italy)
Umberto Berardi (Italy)
Anna Bogdan (Poland)
Alberto Cavallini (Italy)
Iolanda Colda (Romania)
Stefano Corgnati (Italy)
Annunziata D'Orazio (Italy)
Filippo de' Rossi (Italy)
Livio de Santoli (Italy)
Marco Dell'Isola (Italy)
Giorgio Ficco (Italy)
Marco Filippi (Italy)
Manuel C. Gameiro da Silva (Portugal)
Cesare M. Joppolo (Italy)
Dimitri Kaliakatsos (Italy)
Essam Khalil (Egypt)
Jarek Kurnitski (Latvia)
Renato M. Lazzarin (Italy)
Catalin Lungu (Romania)
Anna Magrini (Italy)
Zoltán Magyar (Hungary) 
Rita M.A. Mastrullo (Italy)
Livio Mazzarella (Italy)
Arsen Melikov (Denmark)
Gino Moncalda Lo Giudice (Italy)
Boris Palella (Italy)
Federico Pedranzini (Italy)
Fabio Polonara (Italy)
Piercarlo Romagnoni (Italy)
Francesco Ruggiero (Italy)
Luigi Schibuola (Italy)
Giovanni Semprini (Italy)
Jorn Toftum (Denmark)
Timothy Wentz (USA)
Claudio Zilio (Italy)


*************************

Editor-in-Chief
Giorgio Albonetti

Management Board
Filippo Busato
Paolo Cervio
Luca Piterà
Erika Seghetti

Editorial Board
Carmine Casale
Paolo Cervio
Luigi Gazzi
Pino Miolli
Marco Noro
Luca Alberto Piterà
Gabriele Raffaellini
Valentina Serra 
Luigi Schibuola
Claudio Zilio

Publishing Editor
Erika Seghetti
redazione.aicarrjournal@quine.it 

Sales
dircom@quine.it

Printing
Aziende Grafiche Printing Srl
Peschiera Borromeo (MI)


Quine Srl - LSWR GROUP
Via G. Spadolini, 7
20141 Milano - Italy
Ph. 0039 (0)2-49756990
Fax 0039 (0)2-70057190
www.quine.it


Impianti con refrigeranti a basso GWP: quanto sono sicuri i raccordi?
Assessment of leakage rate and durability of field-made mechanical joints, for systems using low-GWP flammable refrigerants


N. Lawrence1, S. Raj2, S. Elbel1

Show more: Authors information and Publication history

Abstract

The conversion of refrigeration and air-conditioning systems to low-GWP refrigerants, such as HFOs, has raised many concerns about the flammability of potential replacement refrigerants, particularly regarding the potential leakage of flammable refrigerant from mechanical joints. This paper presents the results of a study investigating the durability and leakage rate of different types of field-made joints used in refrigeration and air-conditioning systems, focusing on flame-free joining methods and systems with flammable refrigerants. Three different types of fittings were investigated: Press/crimp fittings, compression fittings, and flare fittings. For each type of fitting, two different sizes were used as well as two different tubing materials (copper and aluminum). Brazed joints were also investigated as a baseline. Durability testing in the form of pressure-temperature thermal cycling, freeze-thaw cycling, and vibration testing was performed on all combinations of fittings. Refrigerant leakage rates were also determined for all combinations of fittings.

Keywords

Low GWP refrigerants, flammable refrigerants, mechanical joining methods, endurance tests, refrige- rant leakage rate

PDF