AiCARR journal
AiCARR
CURRENT ISSUE      ARCHIVE      SUBMIT YOUR PAPER      GUIDE FOR AUTHOR      CONTACTS      SUBSCRIPTION      FOR ADVERTISERS     

EDITORS IN CHIEF
Francis Allard (France)
Filippo Busato (Italy)

HONORARY EDITOR
Bjarne Olesen (Denmark)

ASSOCIATE EDITORS
Karel Kabele (Czech Republic)
Valentina Serra (Turin - Italy)

SCIENTIFIC COMMITTEE
Ciro Aprea (Italy)
William Bahnfleth (USA)
Marco Beccali (Italy)
Anna Bogdan (Poland)
Alberto Cavallini (Italy)
Iolanda Colda (Romania)
Stefano Corgnati (Italy)
Annunziata D'Orazio (Italy)
Filippo de' Rossi (Italy)
Livio de Santoli (Italy)
Marco Dell'Isola (Italy)
Giorgio Ficco (Italy)
Marco Filippi (Italy)
Manuel C. Gameiro da Silva (Portugal)
Cesare M. Joppolo (Italy)
Dimitri Kaliakatsos (Italy)
Essam Khalil (Egypt)
Jarek Kurnitski (Latvia)
Renato M. Lazzarin (Italy)
Catalin Lungu (Romania)
Anna Magrini (Italy)
Zoltán Magyar (Hungary) 
Rita M.A. Mastrullo (Italy)
Livio Mazzarella (Italy)
Arsen Melikov (Denmark)
Gino Moncalda Lo Giudice (Italy)
Boris Palella (Italy)
Federico Pedranzini (Italy)
Fabio Polonara (Italy)
Piercarlo Romagnoni (Italy)
Francesco Ruggiero (Italy)
Luigi Schibuola (Italy)
Giovanni Semprini (Italy)
Jorn Toftum (Denmark)
Timothy Wentz (USA)
Claudio Zilio (Italy)


*************************

Publisher
Marco Zani

Management Board
Filippo Busato
Paolo Cervio
Luca Piterà
Erika Seghetti
Marco Zani

Editorial Board
Carmine Casale
Paolo Cervio
Luigi Gazzi
Pino Miolli
Marco Noro
Luca Alberto Piterà
Gabriele Raffaellini
Valentina Serra 
Luigi Schibuola
Claudio Zilio

Publishing Editor
Erika Seghetti
redazione.aicarrjournal@quine.it 

Sales
dircom@lswr.it
Ph. 0039 (0)2-88184.404

Printing
Aziende Grafiche Printing Srl
Peschiera Borromeo (MI)

Quine Srl - LSWR GROUP
Via G. Spadolini, 7
20141 Milano - Italy
Ph. 0039 (0)2-49756990
Fax 0039 (0)2-70057190
www.quine.it


Condizionamento dell'aria nel resort
Air conditioning solutions for a resort hotel


A. Zullo1, F. Maragno1, E. D'Argenzio2

Show more: Authors information and Publication history

Abstract

The following article deals with some design and installation aspects considered during the redevelopment of a resort hotel for air conditioning system. In addition to the type of system, it is explained which was the best choice on the type of indoor unit to be used inside the rooms, as the problem was linked to the reduced height of the false ceiling. The type of indoor units compared are concealed duct and 1 way cassette types. The study of the comparison is done evaluating the results given by CFD and noise analysis, added to the evaluation of the installation times and costs of the two options.

Keywords

thermal comfort; heat recovery VRF; CFD analysis; noise analysis; hotel redevelopment design; thermal distribution


PDF