AiCARR journal
AiCARR

EDITORS IN CHIEF
Francis Allard (France)
Filippo Busato (Italy)

HONORARY EDITOR
Bjarne Olesen (Denmark)

ASSOCIATE EDITORS
Karel Kabele (Czech Republic)
Valentina Serra (Turin - Italy)

SCIENTIFIC COMMITTEE
Ciro Aprea (Italy)
William Bahnfleth (USA)
Marco Beccali (Italy)
Umberto Berardi (Italy)
Anna Bogdan (Poland)
Alberto Cavallini (Italy)
Iolanda Colda (Romania)
Stefano Corgnati (Italy)
Annunziata D'Orazio (Italy)
Filippo de' Rossi (Italy)
Livio de Santoli (Italy)
Marco Dell'Isola (Italy)
Giorgio Ficco (Italy)
Marco Filippi (Italy)
Manuel C. Gameiro da Silva (Portugal)
Cesare M. Joppolo (Italy)
Dimitri Kaliakatsos (Italy)
Essam Khalil (Egypt)
Jarek Kurnitski (Latvia)
Renato M. Lazzarin (Italy)
Catalin Lungu (Romania)
Anna Magrini (Italy)
Zoltán Magyar (Hungary) 
Rita M.A. Mastrullo (Italy)
Livio Mazzarella (Italy)
Arsen Melikov (Denmark)
Gino Moncalda Lo Giudice (Italy)
Boris Palella (Italy)
Federico Pedranzini (Italy)
Fabio Polonara (Italy)
Piercarlo Romagnoni (Italy)
Francesco Ruggiero (Italy)
Luigi Schibuola (Italy)
Giovanni Semprini (Italy)
Jorn Toftum (Denmark)
Timothy Wentz (USA)
Claudio Zilio (Italy)


*************************

Editor-in-Chief
Giorgio Albonetti

Management Board
Filippo Busato
Paolo Cervio
Luca Piterà
Erika Seghetti

Editorial Board
Carmine Casale
Paolo Cervio
Luigi Gazzi
Pino Miolli
Marco Noro
Luca Alberto Piterà
Gabriele Raffaellini
Valentina Serra 
Luigi Schibuola
Claudio Zilio

Publishing Editor
Erika Seghetti
redazione.aicarrjournal@quine.it 

Sales
dircom@quine.it

Printing
Aziende Grafiche Printing Srl
Peschiera Borromeo (MI)


Quine Srl - LSWR GROUP
Via G. Spadolini, 7
20141 Milano - Italy
Ph. 0039 (0)2-49756990
Fax 0039 (0)2-70057190
www.quine.it


Theoretical and actual energy behaviour of a cost-optimal based Nearly-Zero Energy Building
Prestazione energetica ideale e reale di un edificio ad energia quasi zero


I. Abbŕ1, G. Crespi1, C. Lingua1, C. Becchio cristina.becchio@polito.it1, S. P. Corgnati1

Show more: Authors information and publication history

Abstract

Nowadays, Nearly-Zero Energy Buildings (NZEBs) seem to be the best solution to achieve the ambitious decarbonisation targets defined by the European Union for the building sector, thanks to the combination of performing envelope and efficient technological systems. In this framework, energy simulation proves to be an effective tool for the preliminary design phase, to evaluate different retrofit scenarios. Despite the high-quality performance of the simulations, theoretical consumptions result different from actual ones. The main reason for this discrepancy lies in the presence of the occupants and in their interaction with the energy systems, a factor that the energy simulation cannot fully capture. This paper aims to verify the gap between theoretical and actual values in a real NZEB located in the North of Italy. Ideal consumptions of this all-electric single-family house, resulting from energy certification and dynamic simulations, were compared with the real ones, coming from the electricity bill.

Keywords

Nearly-Zero Energy Building, Cost-optimal analysis, Occupant behaviour, Energy simulation,Theoretical and actual consumptions

DOI

10.36164/AiCARRJ.62.03.04